Collaboration Activities:
- Collaborations to further develop the DRO
- Collaborations to use the DRO to test ASL analysis software
External Links:
We have developed digital reference object software for Arterial Spin Labelling. This can generate raw synthetic raw ASL data (in BIDS compliant format) based on input ground truth (perfusion rate, transit time, t1, t2, m0 etc), sequence parameters, and data output type. This software was developed as part of the ASPIRE project, a Eurostars funded collaboration between Gold Standard Phantoms, VUmc Amsterdam (ExploreASL) and mediri GmbH, with the specific intentions for it being used in software development and integration testing of ExploreASL. The software is released under an open source MIT license and we invite the rest of the ASL community to provide feedback, fork and contribute.
- ISMRM 2021 Abstract accepted for digital poster
Date added: 2021-03-16
Collaboration Activities:
- Collaborations with researchers
External Links:
This DRO was built to assess the accuracy of K^trans estimations by competing teams as part of the Osipi TF6.2 DCE-MRI perfusion analysis challenge. It is based on a two-compartment exchange model (2CXM) and the signal model of a spoiled gradient-echo sequence in steady-state. It contains multiple structures with specifications of normal gray matter, normal white matter, tumor, necrosis, and arterial input function (AIF) taking a range of values for PS, V e , V p , and F. Temporal sampling time is dt = 6s, the total scan time is 6 min and Rician noise has been simulated.
Date added: 2021-03-16
Collaboration Activities:
- Collaborations with researchers
- Standardisation and Validation
- Invivo Studies
- DROs
External Links:
We use QASPER for ASL sequence development and software evaluation purposes; ASL "reference" scans using manufacturer's sequences/protocols are compared with inhouse research sequence developments (parallel, multiband, inline motion correction, alternative reconstruction algorithms, etc.). For reference, stability and homogeneity checks we have acquired a large number of phantom and invivo scans which data might be shared. Our interest is in collaborations to work on multi-center studies, standardization and optimazation of clinical ASL approaches.
Date added: 2021-10-27
Collaboration Activities:
- Collaborations with researchers
- Standardisation and Validation
- Invivo Studies
External Links:
A longer description of the contribution, up to 200 words
Date added: 2021-10-27
Collaboration Activities:
- Sharing design and print files for the prototype phantom
- Open to new collaborations with researchers interested in this approach
External Links:
Impinging jets, driven by a peristaltic pump, were used to achieve perfusion-like mixing of magnetically labeled inflowing fluid within a single perfusion compartment. Fluid dynamics simulations predicted that maximum mixing would occur near the central axis of the perfusion compartment. Experimentally observed signal changes within this region were reproducible and well fit by the standard Buxton General Kinetic Model. Calculated perfusion rates, averaged over the entire phantom volume, agreed with the expected volumetric flow rates provided by the flow pump. Phantom sensitivity to pCASL labeling parameters was also demonstrated. Observed perfusion and transit time values were reproducible and within the physiological range for brain perfusion.
- A perfusion phantom for ASL MRI based on impinging jets
- A Single-Compartment Perfusion Phantom for ASL-MRI
Date added: 2021-10-27